Einstein coefficients, stimulated emission and population inversion

Database › Physics › Optics › Lasers

OPT-0028LawUndergraduate

Absorption, spontaneous emission and stimulated emission are linked by the Einstein coefficients; amplification requires a population inversion, impossible in thermal equilibrium.

$$\frac{A_{21}}{B_{21}}=\frac{8\pi h\nu^3}{c^3},\qquad g_1B_{12}=g_2B_{21},\qquad\frac{B_{21}\rho(\nu)}{A_{21}}=\frac{1}{e^{h\nu/k_BT}-1},\qquad\gamma(\nu)\propto\Big(N_2-\frac{g_2}{g_1}N_1\Big)$$

Explanation

Einstein required that the rates $B_{12}\rho N_1=A_{21}N_2+B_{21}\rho N_2$ balance in thermal equilibrium with Boltzmann populations and the Planck spectral energy density $\rho(\nu)$; this fixes the relations above. A stimulated photon has the same frequency, direction, phase and polarisation as the stimulating one, which is the origin of laser coherence.

The gain coefficient is proportional to $N_2-(g_2/g_1)N_1$; positive gain needs a population inversion. A two-level system pumped optically can at best equalise populations, so lasers use three- or four-level schemes in which pumping and lasing involve different levels. Oscillation starts when the round-trip gain exceeds the cavity losses.

Example 1

For a 600 nm transition in a body at 3000 K, find the ratio of stimulated to spontaneous emission rates.

Solution

$h\nu/k_BT=\frac{hc}{\lambda k_BT}=\frac{(6.63\times10^{-34})(3.0\times10^8)}{(6.0\times10^{-7})(1.38\times10^{-23})(3000)}\approx8.0$, so the ratio is $1/(e^{8.0}-1)\approx3.4\times10^{-4}$: thermal sources emit almost entirely spontaneously in the visible.

Example 2

Explain why continuous optical pumping of a two-level system cannot create a population inversion.

Solution

The pump light drives absorption $1\to2$ and stimulated emission $2\to1$ with the same coefficient (for equal degeneracies). As $N_2$ approaches $N_1$ the net absorption vanishes; with spontaneous decay as well, $N_2<N_1$ always. The medium becomes transparent (saturates) but never amplifies.

Related entries