Mach–Zehnder and Sagnac interferometers

Database › Physics › Optics › Optical principles

OPT-0038ResultUndergraduateEntrance exam

Mach–Zehnder interferometers convert phase differences between two separated arms into intensity; Sagnac interferometers detect rotation through the phase difference 8πAΩ/λc of counter-propagating beams.

$$I_{\rm out}=I_0\cos^2\frac{\Delta\phi}{2},\quad\Delta\phi=\frac{2\pi}{\lambda}\int(n_1-n_2)\,dl;\qquad\Delta\phi_{\rm Sagnac}=\frac{8\pi NA\,\Omega}{\lambda c}$$

Explanation

In a Mach–Zehnder the beams travel well-separated paths, so a sample (gas cell, plasma, flame, modulator waveguide) can be placed in one arm; the output ports carry complementary fringes. It underlies integrated-optic modulators and many sensors.

In a Sagnac loop both beams share the same path in opposite directions, so it is insensitive to path changes but sensitive to rotation: in the rotating frame the co-rotating beam takes longer. With $N$ turns of fibre enclosing area $A$ the phase scales with $NA$ (fibre-optic gyroscope); in ring lasers the effect appears as a beat frequency.

Example 1

A 10 cm cell in one arm of a Mach–Zehnder is slowly filled with air ($n-1=2.9\times10^{-4}$) at 633 nm. How many fringes pass?

Solution

$N=\frac{(n-1)L}{\lambda}=\frac{2.9\times10^{-4}\times0.10}{6.33\times10^{-7}}\approx46$ fringes; counting them measures $n-1$ to better than 1 %.

Example 2

A fibre gyroscope has 1000 turns of radius 5.0 cm at 1.55 μm. Find the Sagnac phase due to Earth's rotation ($7.3\times10^{-5}$ rad/s).

Solution

$\Delta\phi=\frac{8\pi(1000)\pi(0.050)^2(7.3\times10^{-5})}{(1.55\times10^{-6})(3.0\times10^8)}\approx3.1\times10^{-5}$ rad, measurable with careful phase modulation and detection.