Zernike phase-contrast microscopy

Database › Physics › Optics › Optical design

OPT-0068MethodUndergraduate

Transparent specimens only shift the phase of light; Zernike's phase-contrast microscope retards the undiffracted light by a quarter wave so that small phase differences become intensity differences proportional to the phase.

$$t=e^{i\phi(x)}\approx1+i\phi\ \to\ e^{i\pi/2}+i\phi:\qquad I\approx1+2\phi\ \ (\phi\ll1)$$

Explanation

A weak phase object transmits $1+i\phi$: the unscattered light (the "1", focused to a point in the Fourier plane) and the weakly diffracted light ($i\phi$) are $90^\circ$ out of phase, so they do not interfere and the intensity $|1+i\phi|^2\approx1$ shows nothing. A phase ring in the back focal plane shifts the direct light by another $\pm90^\circ$, bringing the two into phase or antiphase: $I\approx1\pm2\phi$.

Contrast is improved further by attenuating the direct light. The method made living cells visible without staining (Nobel Prize 1953); differential interference contrast and quantitative phase imaging extend the idea.

Example 1

An organelle 1.0 μm thick has index 0.020 higher than the cytoplasm. Find the phase shift at 550 nm and the expected phase-contrast intensity change.

Solution

$\phi=\frac{2\pi(0.020)(1.0\ \mu\mathrm m)}{0.55\ \mu\mathrm m}\approx0.23$ rad, so $I\approx1\pm0.46$: a contrast of about 46 %, versus $\phi^2\approx5\%$ in an ordinary bright-field image.

Example 2

Explain why defocusing a bright-field microscope slightly makes transparent cells visible.

Solution

Defocus adds a propagation phase that depends on spatial frequency, converting part of the $i\phi$ term into a real (intensity) term — a crude, frequency-dependent version of the Zernike phase shift.